            <title>sentron</title>
            <link>https://www.lamaplc.com/doku.php?id=meas:sentron&amp;rev=1780673444&amp;do=diff</link>
            <description>Differences between the Siemens SENTRON PAC2xxx, PAC3xxx, and PAC4xxx

The differences in structure among the Siemens SENTRON PAC2xxx, PAC3xxx, and PAC4xxx power monitoring series are summarised below, focusing on their physical placement, measurement accuracy, communication capabilities, and compliance status.</description>
            <author>vamsan@undisclosed.example.com (vamsan)</author>
            <pubDate>Fri, 05 Jun 2026 15:30:44 +0000</pubDate>
        </item>
        <item>
            <title>eastron_smart_x96</title>
            <link>https://www.lamaplc.com/doku.php?id=meas:eastron_smart_x96&amp;rev=1780669242&amp;do=diff</link>
            <description>lamaPLC: Communication with Eastron Smart X96

[lamaPLC: Communication with Eastron Smart X96]
The Smart X96-5 is a precise multifunction power meter that operates using a traditional wired 1/5A current transformer. It can be configured for 1p2w, 3p3w, and 3p4w systems, measuring parameters such as Amps, Volts, Power, and Current Demand (with both sliding and fixed scale options). It also monitors Power Factor, imported and exported kWh, individual harmonics, phase sequence, and includes a phase…</description>
            <author>vamsan@undisclosed.example.com (vamsan)</author>
            <pubDate>Fri, 05 Jun 2026 14:20:42 +0000</pubDate>
        </item>
        <item>
            <title>xtm_35_sc - [Wiring] </title>
            <link>https://www.lamaplc.com/doku.php?id=meas:xtm_35_sc&amp;rev=1780669165&amp;do=diff</link>
            <description>LamaPLC: XTM35SC Energy meter with Modbus communication

[XTM35SC]
Other unit names:

	*  VE EMDIN02



The XTM35SC is an inexpensive current meter that can be purchased (e.g. on Amazon). It measures consumption, voltage and current on one phase. It does not require an external measuring ring. Suitable for home automation and smaller equipment. Of course, it is not MID compliant. The measurement results can also be queried remotely via Modbus RTU communication.23312</description>
            <author>vamsan@undisclosed.example.com (vamsan)</author>
            <pubDate>Fri, 05 Jun 2026 14:19:25 +0000</pubDate>
        </item>
        <item>
            <title>start - [Energy meters (EM)] </title>
            <link>https://www.lamaplc.com/doku.php?id=meas:start&amp;rev=1780669134&amp;do=diff</link>
            <description>lamaPLC: Measurement

Energy meters (EM)
[Eastron SDM 630 Energy Meter] Eastron SDM 630 
3-phase Energy Meter with Modbus communication + Modbus map[Eastron SDM230] Eastron SDM 230 
1-phase Energy Meter with Modbus communication + Modbus map[Eastron Smart X96] Eastron Smart X96 
3-phase Energy Meter with Modbus communication + Modbus map[DS100] DS100 
3-phase Energy Meter with Modbus communication + Modbus map</description>
            <author>vamsan@undisclosed.example.com (vamsan)</author>
            <pubDate>Fri, 05 Jun 2026 14:18:54 +0000</pubDate>
        </item>
        <item>
            <title>bg_e_tech_ds100</title>
            <link>https://www.lamaplc.com/doku.php?id=meas:bg_e_tech_ds100&amp;rev=1780668633&amp;do=diff</link>
            <description>lamaPLC: B+G E-Tech DS100 Energy Meter with Modbus

This series&#039; digital bidirectional power meter is built for direct measurement in 3-phase AC systems, supporting loads up to 100 A. It is MID B&amp;D certified by SGS UK.
[DS100 Serie Modbus][DS100 Serie Modbus][DS100 Serie Modbus]
Technical data

	*  Type designation: DS100-009 (Article no. 1042204-M23)23312</description>
            <author>vamsan@undisclosed.example.com (vamsan)</author>
            <pubDate>Fri, 05 Jun 2026 14:10:33 +0000</pubDate>
        </item>
        <item>
            <title>eastron_sdm_modbus - [32-bit (2 words) input registers] </title>
            <link>https://www.lamaplc.com/doku.php?id=meas:eastron_sdm_modbus&amp;rev=1780667742&amp;do=diff</link>
            <description>Modbus communication

Read Limits: Do not attempt to read more than 40 parameters (80 registers) in a single Modbus request to avoid exception errors.

RS485 communication interface, MODBUS RTU protocol:

	*  Baudrate: 9600 Baud (default, can be set)</description>
            <author>vamsan@undisclosed.example.com (vamsan)</author>
            <pubDate>Fri, 05 Jun 2026 13:55:42 +0000</pubDate>
        </item>
        <item>
            <title>eastron_sdm_630</title>
            <link>https://www.lamaplc.com/doku.php?id=meas:eastron_sdm_630&amp;rev=1780667714&amp;do=diff</link>
            <description>LamaPLC: Eastron SDM 630 Energy Meter with Modbus communication

[Eastron SDM 630 Energy Meter]
The Eastron SDM630 is a series of three-phase, multifunctional DIN-rail-mounted energy meters used to measure and monitor electrical parameters in industrial, commercial, and residential applications. It is known for its high accuracy, compact design, and communication interfaces.1252</description>
            <author>vamsan@undisclosed.example.com (vamsan)</author>
            <pubDate>Fri, 05 Jun 2026 13:55:14 +0000</pubDate>
        </item>
        <item>
            <title>start</title>
            <link>https://www.lamaplc.com/doku.php?id=sensor:start&amp;rev=1780667065&amp;do=diff</link>
            <description>LamaPLC: Sensors

The page below lists sensors compatible with microcontrollers such as Arduino, Raspberry Pi Nano, ESP32, and ESP8266, as they operate at 3.3V/5V signal levels.

The search is easier in the summarized abbreviation index, depending on the type designation.

Temperature, Humidity, Air-pressure, Gas, Air-quality Sensors and Module</description>
            <author>vamsan@undisclosed.example.com (vamsan)</author>
            <pubDate>Fri, 05 Jun 2026 13:44:25 +0000</pubDate>
        </item>
        <item>
            <title>start</title>
            <link>https://www.lamaplc.com/doku.php?id=display:start&amp;rev=1780667034&amp;do=diff</link>
            <description>lamaPLC: Displays

Display moduls
[DM56A04 / DM36B06 digital tube display] DM56A04 / DM36B06 
digital tube display with Modbus Communication[TM1650 7-Segment Display with I²C like or Modbus Communication] TM1650 
7-Segment Display with I²C like or Modbus Communication[HT16K33 7-segment display] HT16K33 
7-segment display with I²C communication[HT16K33 7-segment display] HT16K33 
7-segment display with I²C communication[TM1637 7-segment display] TM1637 
7-segment display with I²C-like protocol…</description>
            <author>vamsan@undisclosed.example.com (vamsan)</author>
            <pubDate>Fri, 05 Jun 2026 13:43:54 +0000</pubDate>
        </item>
        <item>
            <title>start</title>
            <link>https://www.lamaplc.com/doku.php?id=actor:start&amp;rev=1780666951&amp;do=diff</link>
            <description>lamaPLC: Actors

Switches / Relays / SSRs
[Multi-channel optocoupled relay module] Multi-channel optocoupled relay module 
(HL-54, HW-316, KY-019, HFD4/3-S, FY-T734)[Multi-channel Solid State Relay Module] Multi-channel Solid State Relay (SSR) Module 
(SSR G3MB-202P)
TEC / Peltier Elements
[TEC / Peltier Elements] TEC / Peltier Elements
MPPT (Maximum Power Point Tracking)
[SD05CRMA] MPPT 
(SD05CRMA)
LED controllers / addressable LEDs
[WS28xx: addressable RGB LEDs] WS28xx: addressable RGB LEDs
Mo…</description>
            <author>vamsan@undisclosed.example.com (vamsan)</author>
            <pubDate>Fri, 05 Jun 2026 13:42:31 +0000</pubDate>
        </item>
        <item>
            <title>eastron_sdm_modbus</title>
            <link>https://www.lamaplc.com/doku.php?id=sensor:eastron_sdm_modbus&amp;rev=1780661604&amp;do=diff</link>
            <description>Modbus communication

Read Limits: Do not attempt to read more than 40 parameters (80 registers) in a single Modbus request to avoid exception errors.

RS485 communication interface, MODBUS RTU protocol:

	*  Baudrate: 9600 Baud (default, can be set)</description>
            <author>vamsan@undisclosed.example.com (vamsan)</author>
            <pubDate>Fri, 05 Jun 2026 12:13:24 +0000</pubDate>
        </item>
        <item>
            <title>conv_word_array_to_real_array_labview.png - created</title>
            <link>https://www.lamaplc.com/doku.php?image=sensor%3Aconv_word_array_to_real_array_labview.png&amp;ns=sensor&amp;rev=1780661554&amp;tab_details=history&amp;media_do=diff&amp;do=media</link>
            <description>&lt;img src=&quot;https://www.lamaplc.com/lib/exe/fetch.php?w=500&amp;amp;h=500&amp;amp;tok=f404f3&amp;amp;media=sensor:conv_word_array_to_real_array_labview.png&quot; alt=&quot;conv_word_array_to_real_array_labview.png&quot; loading=&quot;lazy&quot; width=&quot;500&quot; height=&quot;500&quot; /&gt;</description>
            <author>vamsan@undisclosed.example.com (vamsan)</author>
            <pubDate>Fri, 05 Jun 2026 12:12:34 +0000</pubDate>
        </item>
        <item>
            <title>eastron_sdm_230</title>
            <link>https://www.lamaplc.com/doku.php?id=sensor:eastron_sdm_230&amp;rev=1780660446&amp;do=diff</link>
            <description>LamaPLC: Eastron SDM 230 with Modbus Communication

[Eastron SDM230]

The Eastron SDM230 Modbus MID 1-phase kWh meter is ideal for the precise monitoring of, for example, a solar panel system, a charging station, a heat pump, or another 1-phase group of your choice. On the illuminated LCD screen, you can immediately see how many kWh the respective system consumes or produces, and it is used for official registration and billing of the measurement data. For example, if you want to bill a tenant f…</description>
            <author>vamsan@undisclosed.example.com (vamsan)</author>
            <pubDate>Fri, 05 Jun 2026 11:54:06 +0000</pubDate>
        </item>
        <item>
            <title>sdm630.csv - created</title>
            <link>https://www.lamaplc.com/doku.php?image=sensor%3Asdm630.csv&amp;ns=sensor&amp;rev=1780660273&amp;tab_details=history&amp;media_do=diff&amp;do=media</link>
            <description>&lt;img src=&quot;https://www.lamaplc.com/lib/images/fileicons/svg/csv.svg&quot; alt=&quot;sdm630.csv&quot; loading=&quot;lazy&quot; width=&quot;500&quot; height=&quot;500&quot; /&gt;</description>
            <author>vamsan@undisclosed.example.com (vamsan)</author>
            <pubDate>Fri, 05 Jun 2026 11:51:13 +0000</pubDate>
        </item>
        <item>
            <title>eastron_sdm_630</title>
            <link>https://www.lamaplc.com/doku.php?id=sensor:eastron_sdm_630&amp;rev=1780658332&amp;do=diff</link>
            <description>LamaPLC: Eastron SDM 630 Energy Meter with Modbus communication

[Eastron SDM 630 Energy Meter]
The Eastron SDM630 is a series of three-phase, multifunctional DIN-rail-mounted energy meters used to measure and monitor electrical parameters in industrial, commercial, and residential applications. It is known for its high accuracy, compact design, and communication interfaces.00</description>
            <author>vamsan@undisclosed.example.com (vamsan)</author>
            <pubDate>Fri, 05 Jun 2026 11:18:52 +0000</pubDate>
        </item>
        <item>
            <title>st7567a_1.png - created</title>
            <link>https://www.lamaplc.com/doku.php?image=display%3Ast7567a_1.png&amp;ns=display&amp;rev=1779287887&amp;tab_details=history&amp;media_do=diff&amp;do=media</link>
            <description>&lt;img src=&quot;https://www.lamaplc.com/lib/exe/fetch.php?w=500&amp;amp;h=500&amp;amp;tok=f73b9d&amp;amp;media=display:st7567a_1.png&quot; alt=&quot;st7567a_1.png&quot; loading=&quot;lazy&quot; width=&quot;500&quot; height=&quot;500&quot; /&gt;</description>
            <author>vamsan@undisclosed.example.com (vamsan)</author>
            <pubDate>Wed, 20 May 2026 14:38:07 +0000</pubDate>
        </item>
        <item>
            <title>st7789_1.png - created</title>
            <link>https://www.lamaplc.com/doku.php?image=display%3Ast7789_1.png&amp;ns=display&amp;rev=1779220214&amp;tab_details=history&amp;media_do=diff&amp;do=media</link>
            <description>&lt;img src=&quot;https://www.lamaplc.com/lib/exe/fetch.php?w=500&amp;amp;h=500&amp;amp;tok=d31a3a&amp;amp;media=display:st7789_1.png&quot; alt=&quot;st7789_1.png&quot; loading=&quot;lazy&quot; width=&quot;500&quot; height=&quot;500&quot; /&gt;</description>
            <author>vamsan@undisclosed.example.com (vamsan)</author>
            <pubDate>Tue, 19 May 2026 19:50:14 +0000</pubDate>
        </item>
        <item>
            <title>tube_lnd_712.png - created</title>
            <link>https://www.lamaplc.com/doku.php?image=sensor%3Atube_lnd_712.png&amp;ns=sensor&amp;rev=1778861882&amp;tab_details=history&amp;media_do=diff&amp;do=media</link>
            <description>&lt;img src=&quot;https://www.lamaplc.com/lib/exe/fetch.php?w=500&amp;amp;h=500&amp;amp;tok=09893d&amp;amp;media=sensor:tube_lnd_712.png&quot; alt=&quot;tube_lnd_712.png&quot; loading=&quot;lazy&quot; width=&quot;500&quot; height=&quot;500&quot; /&gt;</description>
            <author>vamsan@undisclosed.example.com (vamsan)</author>
            <pubDate>Fri, 15 May 2026 16:18:02 +0000</pubDate>
        </item>
        <item>
            <title>tube_sbm20.png - created</title>
            <link>https://www.lamaplc.com/doku.php?image=sensor%3Atube_sbm20.png&amp;ns=sensor&amp;rev=1778861601&amp;tab_details=history&amp;media_do=diff&amp;do=media</link>
            <description>&lt;img src=&quot;https://www.lamaplc.com/lib/exe/fetch.php?w=500&amp;amp;h=500&amp;amp;tok=782f08&amp;amp;media=sensor:tube_sbm20.png&quot; alt=&quot;tube_sbm20.png&quot; loading=&quot;lazy&quot; width=&quot;500&quot; height=&quot;500&quot; /&gt;</description>
            <author>vamsan@undisclosed.example.com (vamsan)</author>
            <pubDate>Fri, 15 May 2026 16:13:21 +0000</pubDate>
        </item>
        <item>
            <title>tube_j321.png - created</title>
            <link>https://www.lamaplc.com/doku.php?image=sensor%3Atube_j321.png&amp;ns=sensor&amp;rev=1778861373&amp;tab_details=history&amp;media_do=diff&amp;do=media</link>
            <description>&lt;img src=&quot;https://www.lamaplc.com/lib/exe/fetch.php?w=500&amp;amp;h=500&amp;amp;tok=6215de&amp;amp;media=sensor:tube_j321.png&quot; alt=&quot;tube_j321.png&quot; loading=&quot;lazy&quot; width=&quot;500&quot; height=&quot;500&quot; /&gt;</description>
            <author>vamsan@undisclosed.example.com (vamsan)</author>
            <pubDate>Fri, 15 May 2026 16:09:33 +0000</pubDate>
        </item>
    </channel>
</rss>